Bil, MERCEDES, E 212, 212.154 E 300 Sedan (long wheelbase), Automatic air conditioning (AAC)

Klima Anlæg - Automatic air conditioning (AAC) - 0

Identifikation

Diagnose version: 00 01 20

Boot software number: 8.30.0

Hardwareversion: 9.7.0

Softwareversion: 9.37.3

Software version 1: --

Software version 2: --

Supplier: Hella

Hardware vare nummer: 2128301285

Software part number (customer): 2129022504

Software part number (code): --

Software part number (data): --

Serie nummer: --

Fejlkoder

U11A888: Ukendt fejlkode

Controls

Clear DTC

Levende Data

Refrigerant pressure: 40.20 bar

A/C power consumption: 6.18 A

Outside air temperature: 35.40 °C

Outside temperature: 181.4 °C

Kølemiddeltemperatur: 78.6 °C

Motor Hastighed: 2071 Omdr.

Køretøjs hastighed: 129.0 km/h

Batteri spænding: 12.00 V

Evaporator temperature sensor: 64.3 °C

Interior temperature sensor: 40.2 °C

Interior temperature sensor with integrated fan: 0.0 °C

Left dual sun sensor light intensity: 75 %

Right dual sun sensor light intensity: 37 %

Blower regulator: 38.60 V

Sensors power supply: 12.90 V

Left side air outlet temperature sensor: 39.1 °C

Left front footwell vent air outlet temperature sensor: 216.1 °C

Right side air outlet temperature sensor: 207.1 °C

Right front footwell vent air outlet temperature sensor: 2.5 °C

Right rear passenger compartment footwell vent air outlet temperature sensor: 207.0 °C

'A/C' button has not been pressed: Nej

Outside temperature too low (< -10 ºC): Nej

Torque reduction of refrigerant compressor by control unit 'Combustion engine': Nej

Limitation of refrigerant compressor output due to high coolant temperature: Nej

Combustion engine and air conditioning with integrated control fan motor: Nej

Upper limit value defined for engine speed was exceeded during breaking-in for refrigerant compressor or break-in rocess was faulty: Nej

Blower motor or Blower regulator is defective: Nej

Blower output is too low: Nej

Refrigerant pressure is too high: Nej

Shutoff of refrigerant compressor by engine control unit: Nej

Break-in of refrigerant compressor was not performed: Nej

Circuit 15 OFF or starter ACTUATED: Nej

Refrigerant compressor is defective: Nej

Internal combustion engine's idle speed is unstable: Nej

Internal combustion engine's idle speed is too low: Nej

Refrigerant pressure is too low: Nej

Shutoff of refrigerant compressor via diagnosis function: Nej

Refrigerant circuit underfill: Nej

Coding 'Operation of refrigerant compressor is disabled' is set to 'YES': Nej

Breaking-in of refrigerant compressor was not successful: Nej

Evaporator temperature sensor is defective: Nej

Evaporator temperature is too low (risk of evaporator icing up): Nej

Fault on magnetic clutch: Nej

Evaporator temperature specified value: Nej

Evaporator drying: Nej

High-voltage battery cooling system shutoff valve and evaporator shutoff valve are closed: Nej

Waiting time after opening of valves: Ja

PTC heater booster power consumption: -- A

PTC heater booster: -- V

Heater element 1: --

Heater element 2: --

Heater element 3: --

Heater element 4: --

Heating element 5: --

Left blend air flap actuator motor

Current flap adjustment range: 2081

Stored flap adjustment range: 2328

Position of actuator motor specified by control unit: 5 %

Current position of actuator motor: 61 %

Specified position of actuator motor: -3560 %

Actual position of actuator motor: 27250 %

Right blend air flap actuator motor

Current flap adjustment range: 2071

Stored flap adjustment range: 1090

Position of actuator motor specified by control unit: 35 %

Current position of actuator motor: 11 %

Specified position of actuator motor: -3465 %

Actual position of actuator motor: -911 %

Defroster flap actuator motor

Current flap adjustment range: 664

Stored flap adjustment range: 1907

Position of actuator motor specified by control unit: 65 %

Current position of actuator motor: 29 %

Specified position of actuator motor: 41239 %

Actual position of actuator motor: 31250 %

Air distribution flap actuator motor

Current flap adjustment range: 34855

Stored flap adjustment range: 280

Position of actuator motor specified by control unit: 14 %

Current position of actuator motor: 19 %

Specified position of actuator motor: 27250 %

Actual position of actuator motor: 39161 %

Fresh air/recirculated air flap actuator motor

Current flap adjustment range: 2328

Stored flap adjustment range: 3207

Position of actuator motor specified by control unit: 11 %

Current position of actuator motor: 15 %

Specified position of actuator motor: 29192 %

Actual position of actuator motor: 37907 %

Udgangs test

Controls

A/C refrigerant compressor

Combustion engine and air conditioning with integrated control fan motor

Blæsermotor

Fresh air/recirculated air flap actuator motor

Left blend air flap actuator motor

Right blend air flap actuator motor

Defroster flap actuator motor position

Air distribution flap actuator motor