Car, BMW, Mini Countryman (F60), Air conditioner (IHKA)
Climate control - Air conditioner (IHKA) - 0
Identification
Diagnostic version: 0F 17 C0
Programming date: 14.29.16
Supplier: Siemens
Manufacture date: 10.02.11
DTC
Controls
Clear DTC
Data stream
Auxiliary water pump: --
Temperature display unit: -- sec
Circulating pump: --
Electric auxiliary air heater: --
Coolant type: -- sec
Fitting the water valve: --
Fitting the water valve: --
Present current value for high-voltage on-board electrical system: -- A
Performance mode: --
Supply voltage (high-voltage electric system): -- V
A/C compressor clutch: --
On/Off button: --
Eject button: --
MODE button: --
1 NUMBER button: --
2 NUMBER button: --
3 NUMBER button: --
4 NUMBER button: --
5 NUMBER button: --
6 NUMBER button: --
7 NUMBER button: --
8 NUMBER button: --
1 NUMBER button: --
2 NUMBER button: --
3 NUMBER button: --
4 NUMBER button: --
5 NUMBER button: --
6 NUMBER button: --
7 NUMBER button: --
8 NUMBER button: --
Electric auxiliary heater setpoint value: -- %
Target value of fresh/recirculated air flap: -- %
Target value of defroster flap: -- %
Target value of left front footwell vent flap: -- %
Target value of right front footwell vent flap: -- %
Rear window heater: --
Air conditioning (A/C) button: --
Defrost: --
Max A/C switch: --
Rocker switch positive: --
Rocker switch negative: --
Condensation sensor: -- %
A/C evaporator temperature sensor: -- °C
Left footwell temperature sensor: -- °C
Right footwell temperature sensor: -- °C
Interior air temperature sensor: -- °C
Refrigerant pressure: -- bar
Solar sensor element left: -- W/m2
Solar sensor element right: -- W/m2
Left side ventilation temperature sensor: -- °C
Right side ventilation temperature sensor: -- °C
AUC_SENSOR: --
Fitting the pressure sensor: --
Refrigerant pressure and temperature sensor: --
Terminal 15 status: --
Terminal 30B: --
Terminal 50: --
Terminal R: --
Automatic air recirculation control LED: --
Rear window heating LED: --
Defrost LED: --
A/C button led: --
MAX button LED: --
LED recirculated air: --
Actuators test
Controls
Activate running-in protection for A/C compressor
Deactivate running-in protection for A/C compressor
Blower at 80%
Air distribution flap motor at 0 degrees
Air distribution flap motor at 180 degrees
Mixing air flap at 0%
Mixing air flap at 100%
Fresh-air recirculated-air flap at 0%
Fresh-air recirculated-air flap at 100%
Fresh-air flap at 0%
Fresh-air flap at 100%
Defroster flap at 0%
Defroster flap at 100%
Left front footwell flap at 0%
Left front footwell flap at 100%
Right front footwell flap at 0%
Right front footwell flap at 100%
Mixing air flap at 0%, right
Mixing air flap at 100%, right
Rear temperature/air volume flap at 0%
Rear temperature/air volume flap at 100%
Stratification flap at 0%, left
Stratification flap at 100%, left
Stratification flap at 0%, right
Stratification flap at 100%, right
Addressing flap motors
Flap motor calibration
Activate function LED (PDC)
Display test