LKW, VW, Crafter (2E, 2F) 2006-, 2013 (D), Crafter, CKUC 2.0L TDI BITURBO-CR , 105kW, 98 - Tire pressure monitoring 21V LT3 (TPM21V)
Reifendrucküberwachung - 98 - Tire pressure monitoring 21V LT3 (TPM21V) - 0
Identifikation
MB Hardwarenummer: 9064467821
Diagnoseversion: 3.1
Hardwarenummer: 07.30
Softwarenummer: 07.34
Lieferant: Borg
Diagnoseversion: 03 01
FIN (ursprünglich): --
FIN:
Fehlercode
C141: No CAN message from signal acquisition and actuation module control unit
Controls
Fehlercode löschen
Ist-Werte
Voltage supply at control module: 1108 V
Front or rear sensor localization: Erfolgreich
Left or right sensor localization: Erfolgreich
Geber für Außentemperatur: 33 °C
Reading of main odometer: 538500 km
Zündungstatus: AUS
RDK tire pressure control: Nicht verfügbar
Ländercode: -
Rear RDK decoder antenna: In Ordnung
Left front wheel electronics identification number: 10102B2
Right front wheel electronics identification number: 30102D4
Right rear wheel electronics identification number: 50102F6
Left rear wheel electronics identification number: 70102B8
Front axle tire pressure: 1 Bar
Rear axle tire pressure: 6 Bar
NHTSA coding: Aktiv
Speicher Nachricht
Message 1: wheel electronics identification number: A1 00 00 B2
Message 1: position: Hinten links
Message 1: tire pressure (Specified pressure): 4 Bar
Message 1: tire temperature: 147 °C
Message 1: tire pressure: 3 Bar
Message 1: kilometer reading: 533040 km
Message 1: readout in multifunction display: Correct tire pressure
Message 1: ambient temperature: 86 °C
Message 2: wheel electronics identification number: B3 00 00 C4
Message 2: position: Vorne links
Message 2: tire pressure (Specified pressure): 0 Bar
Message 2: tire temperature: -50 °C
Message 2: tire pressure: 0 Bar
Message 2: kilometer reading: 0 km
Message 2: readout in multifunction display: No warning
Message 2: ambient temperature: -40 °C
Message 3: wheel electronics identification number: C5 00 00 D6
Message 3: position: Vorne links
Message 3: tire pressure (Specified pressure): 0 Bar
Message 3: tire temperature: -50 °C
Message 3: tire pressure: 0 Bar
Message 3: kilometer reading: 0 km
Message 3: readout in multifunction display: No warning
Message 3: ambient temperature: -40 °C
Message 4: wheel electronics identification number: D7 00 00 E8
Message 4: position: Vorne links
Message 4: tire pressure (Specified pressure): 0 Bar
Message 4: tire temperature: -50 °C
Message 4: tire pressure: 0 Bar
Message 4: kilometer reading: 0 km
Message 4: readout in multifunction display: No warning
Message 4: ambient temperature: -40 °C
Message 5: wheel electronics identification number: E9 00 00 F0
Message 5: position: Vorne links
Message 5: tire pressure (Specified pressure): 0 Bar
Message 5: tire temperature: -50 °C
Message 5: tire pressure: 0 Bar
Message 5: kilometer reading: 0 km
Message 5: readout in multifunction display: No warning
Message 5: ambient temperature: -40 °C
Speicher Aktivierung
Activation no. 1: tire pressure (Wheel electronics no. 1): 3 Bar
Activation no. 1: tire pressure (Wheel electronics no. 2): 3 Bar
Activation no. 1: tire pressure (Wheel electronics no. 4): 1 Bar
Activation no. 1: tire pressure (Wheel electronics no. 3): 2 Bar
Activation no. 1: tire temperature (Wheel electronics no. 1): 63 °C
Activation no. 1: tire temperature (Wheel electronics no. 2): -8 °C
Activation no. 1: tire temperature (Wheel electronics no. 4): 147 °C
Activation no. 1: tire temperature (Wheel electronics no. 3): 98 °C
Activation no. 1: ambient temperature: 32 °C
Activation no. 1: kilometer reading: 538432 km
Activation no. 1: activation sequence: Automatic activation
Activation no. 1: result: Activation was completed successfully
Activation no. 2: tire pressure (Wheel electronics no. 1): 3 Bar
Activation no. 2: tire pressure (Wheel electronics no. 2): 0 Bar
Activation no. 2: tire pressure (Wheel electronics no. 4): 0 Bar
Activation no. 2: tire pressure (Wheel electronics no. 3): 0 Bar
Activation no. 2: tire temperature (Wheel electronics no. 1): 34 °C
Activation no. 2: tire temperature (Wheel electronics no. 2): -50 °C
Activation no. 2: tire temperature (Wheel electronics no. 4): -50 °C
Activation no. 2: tire temperature (Wheel electronics no. 3): -50 °C
Activation no. 2: ambient temperature: 26 °C
Activation no. 2: kilometer reading: 33648 km
Activation no. 2: activation sequence: Automatic activation
Activation no. 2: result: Activation was completed successfully
Activation no. 3: tire pressure (Wheel electronics no. 1): 0 Bar
Activation no. 3: tire pressure (Wheel electronics no. 2): 0 Bar
Activation no. 3: tire pressure (Wheel electronics no. 4): 0 Bar
Activation no. 3: tire pressure (Wheel electronics no. 3): 0 Bar
Activation no. 3: tire temperature (Wheel electronics no. 1): -50 °C
Activation no. 3: tire temperature (Wheel electronics no. 2): -50 °C
Activation no. 3: tire temperature (Wheel electronics no. 4): -50 °C
Activation no. 3: tire temperature (Wheel electronics no. 3): -50 °C
Activation no. 3: ambient temperature: -40 °C
Activation no. 3: kilometer reading: 0 km
Activation no. 3: activation sequence: Automatic activation
Activation no. 3: result: Activation was unsuccessful
Activation no. 4: tire pressure (Wheel electronics no. 1): 0 Bar
Activation no. 4: tire pressure (Wheel electronics no. 2): 0 Bar
Activation no. 4: tire pressure (Wheel electronics no. 4): 0 Bar
Activation no. 4: tire pressure (Wheel electronics no. 3): 0 Bar
Activation no. 4: tire temperature (Wheel electronics no. 1): -50 °C
Activation no. 4: tire temperature (Wheel electronics no. 2): -50 °C
Activation no. 4: tire temperature (Wheel electronics no. 4): -50 °C
Activation no. 4: tire temperature (Wheel electronics no. 3): -50 °C
Activation no. 4: ambient temperature: -40 °C
Activation no. 4: kilometer reading: 0 km
Activation no. 4: activation sequence: Automatic activation
Activation no. 4: result: Activation was unsuccessful
Activation no. 5: tire pressure (Wheel electronics no. 1): 0 Bar
Activation no. 5: tire pressure (Wheel electronics no. 2): 0 Bar
Activation no. 5: tire pressure (Wheel electronics no. 4): 0 Bar
Activation no. 5: tire pressure (Wheel electronics no. 3): 0 Bar
Activation no. 5: tire temperature (Wheel electronics no. 1): -50 °C
Activation no. 5: tire temperature (Wheel electronics no. 2): -50 °C
Activation no. 5: tire temperature (Wheel electronics no. 4): -50 °C
Activation no. 5: tire temperature (Wheel electronics no. 3): -50 °C
Activation no. 5: ambient temperature: -40 °C
Activation no. 5: kilometer reading: 0 km
Activation no. 5: activation sequence: Automatic activation
Activation no. 5: result: Activation was unsuccessful
Stellgliedtest
Controls
Left front signal transfer test
Right front signal transfer test
Left rear signal transfer test
Right rear signal transfer test
Dienstprogramme
Controls
Identifikationsnummer der Radelektronik